Display
5 inch color touchscreen
Relay outputs
Six, one mode each
Sensor inputs
Two card slots
Application models
Eight on one platform
Enclosure
Polycarbonate, Type 4X

Walchem Intuition-6 controllers are wall mount water treatment controllers built on one platform with eight application models. Two card slots, six relay outputs and a universal sensor input cover conductivity, pH, ORP, disinfection and fluorometer duties. Choose the model first, then configure boards, outputs and sensors.

24/7 Sales support
Free shipping over $500
Lifetime tech support
Starting at:

$1,097.00

Availability
In stock
Lead time
3 days
Ships from
US PA - GA - FL - OH - TX
Questions? Urgent request?
Call or text 24/7: +1 (484) 544-0506
Contact us

Display
5 inch color touchscreen
Relay outputs
Six, one mode each
Sensor inputs
Two card slots
Application models
Eight on one platform
Enclosure
Polycarbonate, Type 4X
All possible part numbers

Product details

Headline

Intuition-6 Series water treatment controllers offer a collection of sensors and powerful built-in algorithms for control of chemical metering pumps and valves in a broad range of water treatment applications. A universal sensor input provides extraordinary flexibility, so the same controller can be used with almost any type of sensor needed, with six relay control outputs, six virtual inputs and six virtual outputs in an economical wall-mount package.

Features & benefits

  • Large touchscreen display with icon based programming makes setup easy.
  • Universal sensor input provides extraordinary flexibility; the same controller can be used with almost any type of sensor needed.
  • Six relay control outputs, with complete flexibility in the function of each relay.
  • Combination sensor input and analog input board that adds even more flexibility.
  • Lead/Lag control of relays.
  • Optional dual analog (4-20 mA) input for fluorometers or nearly any other process value.
  • Six virtual inputs and six virtual outputs.
  • Multiple language support allows simple setup no matter where your business takes you.
  • Economical wall-mount package for easy installation.
  • On-screen and web page graphing of sensor values and control output status.
  • Email alarm messages, datalogs, graphs, or system summary reports.
  • Ethernet option for remote access via the internet, LAN, BACnet or Modbus/TCP.
  • The Intuition-6 with amperometric chlorine sensors can be used for reporting chlorine rural measurements in accordance with EPA Method 334.0.

Control modes available on the six relay outputs

On/Off set point, time proportional, pulse proportional (with pulse solid state opto outputs), PID (with pulse solid state opto outputs), Lead/Lag of up to 6 relays, dual set point, timer, bleed or feed based on a water contactor or paddlewheel flow meter input, feed and bleed, feed and bleed with lockout, feed as a percent of bleed, feed as a percent of elapsed time, daily/weekly/2-week/4-week biocide timers with pre-bleed and post-add lockout of bleed, intermittent sampling for boilers with proportional blowdown on a trapped sample, always on unless interlocked, probe wash timer, spike to alternate set point on a timed basis, flow meter ratio, counter timer, dual switch, and diagnostic alarm.

Additional notes

Shared ordering positions (all Intuition-6 models)

  • Relays/wiring: 000 6 powered relays; 100 2 powered 4 dry; 200 2 opto 4 dry; 400 4 opto 2 dry; A00 6 powered with USA pigtails prewired; B00 2 powered with USA pigtails prewired plus 4 dry; C00 2 opto with 20 ft pulse cables plus 4 dry; D00 4 opto with 20 ft pulse cables plus 2 dry.
  • Power cord: B Brazil, D DIN, H hardwired (no power cord), P USA.
  • Input board (choose 2 in alphabetical order): A one sensor input board; B one dual analog input board; C one combination sensor/analog input board; N no sensor input board.
  • Analog outputs: N none; A one dual isolated analog output card.
  • Ethernet: N none; E Ethernet board; M Ethernet board with Modbus TCP + BACnet.

Model parents on this platform

WBL6 boiler controller, WCT6 cooling tower controller, WDS6 disinfectant controller, WPH6 pH controller, WCN6 conductivity controller, WPD6 Pyxis oxidizer + pH controller (brochure 180904.F ordering information), plus WCU6 copper and WNI6 nickel metal-finishing controllers (brochure 180763.E). Sensor-mounting and sensor menus are per model and are not interchangeable.

Included, optional and separately ordered

  • The USB port allows software upgrade, saving all set points from one controller to a USB flash disk for import into another Intuition-6 controller, and data logging of sensor readings and relay activation events.
  • The Ethernet option allows emailing of datalog files in CSV format and alarms to up to eight email addresses, and remote access via a PC connected directly, via a local area network, or via the Walchem Fluent account management server.
  • Analog outputs are an option card with two isolated outputs for retransmission to a chart recorder, datalogger, PLC or other device, or for linear proportional, flow proportional or PID control.
  • Related equipment listed in the WBL A&E specification: orifice union, solenoid valve, metering pump, motorized ball valve, and 100084 sensor extension cable.
  • Recommended spare part in the WBL A&E specification: 102834 fuse, F1, 6 amp 250 V, 5 x 20 mm. Real-time clock battery per manual 180761: model BR2032, 3-volt lithium coin cell, 20 mm diameter.
  • Warranty stated by the manufacturer: 24 months for electronics and 12 months for mechanical parts from date of delivery from the factory or authorized distributor.